R134A Expansion Valve

R134A Expansion Valve

R134A Expansion Valve

Your Right R134A Expansion Valve Supplier in China

Your Right R134A Expansion Valve Supplier in China

Miracle expansion valve  OEM for ALCO, and it has 70 years of manufacturing experience.

So the features of the expansion valve are Low failure rate, high reliability, and excellent cost-performance ratio.

R134A expansion valve for applications such as refrigeration, heat pumps, chillers, and transport cooling.

The Miracle R134A expansion valve is a direct replacement for Danfoss models.

Certified by CE, CQC, ISO, and UL; suitable for sale in the Americas, Europe, Australia, Africa, and the Middle East.

Contact Miracle to get the full details.

Thermostatic Expansion Valve

R134a Expansion Valve CRF CRT Series
  • The CRF/CRT series expansion valves provide refrigeration solutions for R134a air conditioning, commercial refrigeration, and transport refrigeration applications.
  • Applicable evaporation temperature ranges: +20°C, +15°C, +10°C, +5°C, 0°C, -5°C, -10°C, -15°C.
  • Applicable cooling capacity ranges: 0.18–17.8 kW, 0.18–17.92 kW, 0.17–17.28 kW, 0.16–16 kW, 0.15–14.56 kW, 0.13–13.04 kW, 0.11–11.6 kW, 0.1–10.08 kW.

Please contact us for precise model selection.

R134a Expansion Valve NRF RT(E) Series
  • Type: Thermostatic Expansion Valve
  • Supports internal and external balancing.
  • Evaporation temperature: -40~+10°C
  • Cooling capacity ranges: 0.88/ 1.76/ 3.52 /5.28/ 7.04/ 8.8/ 10.56/ 12.32/ 19.36/ 26.4/31.68KW

Please contact us for precise model selection.

R134a Expansion Valve RTB Series
  • Type: Bi-directional throttling thermostatic expansion valve(heat pump expansion valve)
  • Application: heat pump
  • Supports internal and external balancing.
  • Evaporation temperature: +10°C, +4.4°C, -6.7°C, -17.8°C, -29°C, -40°C
  • Cooling capacity ranges: 1.93/ 3.85/ 5.77/ 7.7/ 9.7/ 11.6/ 14.5/ 19.36/ 23.2/ 27.1/ 34.8/ 42.5/ 50.3/ 84.48/ 105.6/ 147.84KW

Please contact us for precise model selection.

R134a Expansion Valve SM Series
  • Type: Replaceable-core expansion valve
  • Application: refrigeration and HVAC
  • Orifice: 0, 1, 2, 3, 4, 5, 6
  • Evaporation temperature: +10°C, +4.4°C, -6.7°C, -17.8°C, -29°C, -40°C
  • Cooling capacity ranges: 0.65, 1.5, 2.5, 4, 6.2, 8.2, 9.5KW
  • Inlet/outlet: 3/8, 1/2

Please contact us for precise model selection.

R134a Expansion Valve TB Series
  • Type: Fixed-superheat thermostatic expansion valve
  • Application: Mini refrigeration system
  • Type of equalization: Internal equalized
  • ODF INLET: 1/4, 1/2 ODF
  • OUTLET: 3/8, 5/8 ODF
  • Capacity: 0.5, 0.8, 1.0, 1.2, 1.6, 2.1, 3.1 ,3.7, 4.6, 4.9, 6.2, 7.2, 9, 9.5, 11.7, 12.4, 14.9, 18.8, 19.8KW

Please contact us for precise model selection.

R134a Expansion Valve TCLE Series
  • The TCLE series consists of take-apart expansion valves designed for high-capacity R134a refrigeration systems.
  • Applicable evaporation temperature ranges: +10°C, +4.4°C, -6.7°C, -17.8°C, -29°C, -40°C.
  • Applicable cooling capacity ranges: 1.1–44.9kW, 1.2–50.6kW, 1.1–48.7kW, 1.1–39kW, 0.72–26.2kW, 0.5–16.9kW.

Please contact us for precise model selection.

R134a Expansion Valve TRFE Series
  • The TCLE series consists of take-apart expansion valves designed for high-capacity R134a refrigeration systems.
  • Applicable evaporation temperature ranges: +10°C, +4.4°C, -6.7°C, -17.8°C, -29°C, -40°C.
  • Applicable cooling capacity ranges: 33–400kW, 37–452.1kW, 43–434kW, 33–348.7kW, 22.3–234.7kW, 14–150kW.

Please contact us for precise model selection.

Heavy Duty R134A Expansion Valve

Heavy Duty R134A Expansion Valve

R134A Expansion Valve for Heat Pump, Commercial refrigeration, and transport air conditioning.

R134A Expansion Valve Accessories

All Miracle R134A expansion valves come with a sensing bulb strap, and the quoted price includes this accessory.

Please get in touch with Miracle if you want to purchase the sensing bulb strap separately.

R134A Expansion Valve Accessories

R134A Expansion Valve Capacity Table

The R134a expansion valve capacity table is for reference only; accurate selection requires consideration of evaporating temperature, condensing temperature, superheat, ambient temperature, and the specific application.

If you encounter any difficulties during the selection process, please contact us. Our professional team will provide a prompt response.

R134aR134a
ModelNominal capacity(KW)ModelNominal capacity(KW)
RTB(T)1/2M1.93NRF(E)
RT(E)
1/4M0.88
RTB(T)1M3.85NRF(E)
RT(E)
1/2M1.76
RTB(T)1-2/3M5.77NRF(E)
RT(E)
1M3.52
RTB(T)2M7.7NRF(E)
RT(E)
1-1/2M5.28
RTB(T)2-3/4M9.7NRF(E)
RT(E)
2M7.04
RTB(T)3-1/3M11.6NRF(E)
RT(E)
2-1/2M8.8
RTB(T)4M14.5NRF(E)
RT(E)
3M10.56
RTB(T)5-1/2M19.36NRF(E)
RT(E)
4M12.32
RTB(T)6-1/2M23.2NRF(E)
RT(E)
5-1/2M19.36
RTBM(T)7-3/4M27.1NRF(E)
RT(E)
7-1/2M26.4
RTBM(T)10M34.8NRF(E)
RT(E)
9M31.68
RTBM(T)12M42.5
RTBM(T)14M50.3
RTBM(T)20M84.48
RTBM(T)25M105.6
RTBM(T)31M147.84
Update cookies preferences