Miracle Ring Vibration Test
Miracle Ring Vibration Test

Miracle Ring Vibration Test

Production NameMiracle Ring
Test DateProduct ModelSAZ0709
Test TypeNew product development

☑

Batch routine

□

Others

□

Test purposeConfirm whether the SAZ0709 aluminum ring for φ8*0.7 aluminum tube ~ φ7*0.8 aluminum tube can meet the requirements of the ISO 14903 7.6  vibration test requirements.
StandardBS EN ISO 14903:2017
Test requirementsPmax=15.1bar.

Tmax=+140℃.

Tmin=-40℃.

Vibration frequency:50Hz.

Amplitude: 0.3mm.

Vacuum helium test condition: leakage rate ≤ 7.5*10-7 Pa.m³ /s at 10 bar differential pressure.

This is only part of the test, for more, please contact us.