Miracle Ring High and Low Temperature Test
Miracle Ring High and Low Temperature Test

Miracle Ring High and Low Temperature Test

Production NameMiracle Ring
Test DateProduct ModelSAZ0709
Test TypeNew product development

Batch routine

Others

Test purposeConfirm whether the SAZ0709 aluminum ring for φ8*0.7 aluminum tube ~ φ7*0.8 aluminum tube can meet the requirements of the ISO 14903 7.6  vibration test requirements.
StandardBS EN ISO 14903:2017
Test requirementsSet the high and low-temperature test cycle temperature -45℃~145℃.

Ensure that the time between the interval below -40 ℃ and the interval above +140 ℃ is not less than 2min.

Set the number of cycles 50 times.

Set the nitrogen valve switch temperature control system to start the switch to pass nitrogen when the temperature is higher than 140℃.